1. Chamber dimension: 600mm(L)x 460mm(W) x 200mm(D)
2. Operating temperature:1250ºC
3. Temperature control:
a. Dual subtitles programmable microcomputer controller. (control accuracy +/- 1ºC)
b. Program ensure system. If the actual temperature and setting temperature deviates more than 2ºC, program automatically holds. If power failure happens and then recovering power, program will automatically start the unfinished program.
c. Two porgram memory systems. Ecah group can be set to 8 sections.
4. Heating elements: The heating cord is made coillike placed in the special grooves on the insultaion bricks. Not easily be damaged and easy to be replaced.
5. Available in foreign voltages, please specify when ordering.